C500-CT012 OMRON C500-CT012


Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced C500-CT012.
Bit-level I/O distribution reduces,
wiring iin the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site C500-CT012.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
CPU Unit: CP1L-M CPU Units with 30 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Transistor output (sinking);
Inputs, 18; Output, 12 C500-CT012.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet OMRON C500-CT012.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. UM: 15 OMRON C500-CT012.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max OMRON C500-CT012. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Connects CQM1H to G730 SYSMAC BUS remote I/O
modules; max. 64 I/O (32 or 16 inputs or outputs, DIP switch selectable)
Number of I/O points per Master: 128
Communications cycle time: 187.5 kbps
Max. transmission distance: 200 m
One master and two expansions allowed per systemUM: 7.2K words.
DM: 6K words.
EM: --.
Instruction processing time (basic instructions): 0.3 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-nectiing Expansion I/O Racks: 2 Racks C500-CT012.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Output method: Transistor sinking.
Inputs: ---.
Outputs: 8.