5 slots.
Requires 1 power modules.
Used to install the old section of the large A series PLC module.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MITSUBISHI Q06CCPU-V-B Manual.
So, sometimes also known as the order control
Q06CCPU-V-B
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read MITSUBISHI Q06CCPU-V-B Manual.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three MITSUBISHI Q06CCPU-V-B Manual.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.Axis of control: 16.
Compact Q170MCPU integrated power supply module, PLC and motion controller,
And built in the packaging equipment used in the incremental synchronous encoder signal and signal detection signal required for the interface,
Do not need to add the appropriate module.
Other multi CPU platform, the need to do a lot of type of configuration in order to ensure the movement of CPU and CPU PLC normal communication,
This will cost engineers a lot of valuable time Q06CCPU-V-B User's Manual.
This thorny problem is solved by the seamless integration of the Q170MCPU and the perfect combination of sequential conntrol and motion control Q06CCPU-V-B User's Manual.
Therefore, simply to carry out a simple set of multiple CPU to start the system, and the subsequent programming and debugging.