Input power: AC100-240V.
Output: DC5V, 5A.
Power supply module can be directly pasted on the printed circuit board of the power supply,
The device is characterized in that a special integrated circuit (ASIC), a digital signal processor (DSP), a microprocessor, a memory, a field programmable gate array (FPGA), and other digital or analog loads are provided L26CPU-CM User's Manual.
In general, this type of module is called the load point (POL) power supply system or the use of point power supply system (PUPS)
L26CPU-CM
Because of the advantages of the modular structure,
The module power supply is widely used in switching devices, access devices, mobile communications, microwave communications and optical transmission, routers and other communication fields and automotive electronics, aerospace, etc L26CPU-CM User's Manual. . "Universal output function: leakage type.
Program capacity: 20K step.
Basic operations processing speed: 60ns.
Communication interface: USB/RS-232.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points.
End cap.
Unable to install display module (L6DSPU-C-CM), RS-232 adapter, RS-422/485 adapter L26CPU-CM User's Manual.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement MITSUBISHI L26CPU-CM Manual MITSUBISHI L26CPU-CM Manual.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s MITSUBISHI L26CPU-CM Manual.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators. "Differential output.
Axis of control: 2.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CCH data can be displayed in real time L26CPU-CM Application.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display L26CPU-CM User's Manual.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action.