Output type: transistor drain.
Output points: 16 points.
Load voltage: DC12/24.
Load current: 0.5A.
Connection mode: terminal row.
Common public end points: 8.
Structured text language is a programming language that describes a program with a structured description of the text.
It is a programming language similar to a high level language A2ASCPU User's Manual. In large and medium
Structured text is often used to describe the relationship between the various variables in the control system based on the PLC system
A2ASCPU
Mainly used for other programming languages more difficult to achieve the user program.
The structured text programming language uses the computer description method to describe the various kinds of relations between the various variables in the system,
Complete the required function or operation A2ASCPU User's Manual.
Most PLC manufacturers use structured text programming language similar to BASIC language, PASCAL language or C language and other advanced languages,
But in order to be convenient, the expression methods of the statement and the types of statements are simplified.
Structured text programming language features: the use of high-level language programming, you can complete the complex control operations,
Need to have a certain level of computer knowledge and programming skills,
Higher requirements for engineering designers A2ASCPU User's Manual. Poor visibility and operability MITSUBISHI A2ASCPU Manual . Input type: DC input, positive / negative public end.
Input points: 8 points.
Enter the response time: 0.2ms below, below 1 MITSUBISHI A2ASCPU Manual . 5ms, 5ms below, 10ms the following.
Rated input voltage / current: DC12V/7mA.
Output form: relay output.
Output points: 8 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/0.5A.
External connection: 3 line /2 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup MITSUBISHI A2ASCPU Manual .
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. Input type: DC input, positive public end / negative public end.
Input points: 16 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor outputt, leakage type A2ASCPU .
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/DC24V/0.5A.
External connection: 1 line /1 line type.
A2C shape terminal.
Type of input and output terminal A2ASCPU User's Manual.
Shape and A2C input and output modules are identical (same mounting dimensions),
Machining and installing holes are not required.