Input points: 32 points
Input mode: DC24V (drain type).
Connection status: connector.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points FX3G-60MR/DS Manual
FX3G-60MR/DS Total points: 32 points.
Input points: 16 points.
Input mode: DC24V (drain / source).
Output points: 16 points.
Output form: Transistor (source).
Connection status: connector.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256 FX3G-60MR/DS Manual.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points. Power: 280kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function FX3G-60MR/DS Manual. The connector is converted to a screw relay terminal.MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 37KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes MITSUBISHI PLC Manual MITSUBISHI PLC Manual.
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection).
If the given acceleration time is too short, the output frequency of the inverter is far more than the change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall MITSUBISHI PLC Manual. Function: 4CH voltage / current output.
Adapter for connecting the left extension function of the CPU module.
CPU module can be connected to the left side up to 6 units. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 0.75kw.
SLD converter rated current: 2.3A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumpttion FX3G-60MR/DS USER'S MANUAL.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control FX3G-60MR/DS Manual.