MITSUBISHI FX2N-2LC USER'S MANUAL Temperature Control Block Manual
Product model: FX2N-2LC
Name: Temperature Control Block
Brand: MITSUBISHI
Sort: USER'S MANUAL
File language: English
Master station module for CC-Link/LT.
I/O control can be used in the province of CC-LINK/LT.
Is to make PLC CC-LINK/LT as the main station of the FX system module.
The master station module and the remote I/O module can be connected by a special connector, and achieve the purpose of the distribution of the province FX2N-2LC Manual.
Up to 64 remote I/O station modules can be connected.
Remote I/O module is assigned a common X, Y soft components,
By using the same procedure as the common input and output FX2N-2LC
Even if the use of 2 points, 4 points of the remote I/O module, the number of soft components can be continuously assigned,
So it can be efficiently allocated I/O. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V FX2N-2LC Manual.
Frequency converter capacity: 400KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the motor FX2N-2LC Manual.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity MITSUBISHI Temperature Control Block Manual MITSUBISHI Temperature Control Block Manual. Axis of control: 1.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
7 operating modules required for easy positioning control are provided.
Type of instruction, please refer to the list in front of you.
One can control a shaft MITSUBISHI Temperature Control Block Manual.
FX3U, PLC FX2N can connect up to 8 units,
PLC FX2NC can connect up to 4 units,
PLC FX3UC can connect up to 7 units, so that it can control more than one independent axis.
Maximum can output 100kHz pulse train.
Positioning control through the control program. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 5.5KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, whichh is mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX2N-2LC USER'S MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX2N-2LC Manual. "
Related products
MITSUBISHI
Input module
FX2N-16EXL-C
MITSUBISHI Input module FX2N-16EXL-C
Total input and output points: 16 points
MITSUBISHI
Input module
FX2N-16EX
MITSUBISHI Input module FX2N-16EX
Total input and output points: 16 points
MITSUBISHI
Pulse output module
FX2N-1PG
MITSUBISHI Pulse output module FX2N-1PG
Axis of control: 1. Applicale PLC:FX1N,
MITSUBISHI
Analog input / output module
FX2N-5A
MITSUBISHI Analog input / output module FX2N-5A
Analog input points: 4. Analog output po