LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> AY60S-UL
MITSUBISHI AY60S-UL User's Manual AY60S-UL Manual
Product model: AY60S-UL
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Long distance bus connection for QCPU.
Applicable models: GT16, GT15, GT11, GT27, GT25. RS-422 1 channel, RS-422/485 1 channel.
Transmission speed: 2 channel total is 115.2kbps.
Control layer /MELSECNET/10 (H) is the middle layer of the whole network system,
Control network which is convenient and high speed processing data transmission between PLC, CNC and other control equipment AY60S-UL User's Manual AY60S-UL
As MELSEC control network MELSECNET/10,
With its good real-time performance, simple network settings, no procedures of the network data sharing concept,
As well as the redundant circuit and so on, has obtained the very high market appraisal,
The number of devices to reach the highest in japan,
In the world is also one of the few AY60S-UL User's Manual.
And MELSECNET/H not only inherited the excellent characteristics of MELSECNET/10,
Also makes the network real-time better, more data capacity,
Further adapt to the needs of the market. Data communication line module (optical cable) Master / local station for A3VTS multiplex system
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add AY60S-UL User's Manual.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations. Storage capacity: 16MB.
Applicable models: A985 (-V) /A975/A970/A960GOT (-B). Input and output points: 2048 points.
Input / output data points: 2048 points.
Program capacity: 30K.
Basic command processing speed (LD command): with 1 s coaxial data communication line function.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a mmeasure of how much the user application can store the number of indicators AY60S-UL Manual .
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words AY60S-UL Manual . Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
Transistor output module
AY60E
MITSUBISHI Transistor output module AY60E
Output points: 16 points. Voltage: DC24V
MITSUBISHI
Transistor output module
AY60
MITSUBISHI Transistor output module AY60
Output points: 16 points. Voltage: DC24V
MITSUBISHI
Transistor output module
AY60EP
MITSUBISHI Transistor output module AY60EP
Output points: 16 points. Voltage: DC24V
MITSUBISHI
Transistor output module
AY60S
MITSUBISHI Transistor output module AY60S
Output points: 16 points. Voltage: DC24/