LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> AJ71QC24
MITSUBISHI AJ71QC24 User's Manual AJ71QC24 Hardware Manual
Product model: AJ71QC24
Name: Communications Module
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
RS-232:1, RS-422/485:1.
Transmission speed: 0.3 ~ 19.2kpbs.
Computer connection function.
Printer / peripheral device connection, BASIC language function.
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc..
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps AJ71QC24 User's Manual AJ71QC24
Design PLC peripheral hardware circuit.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc AJ71QC24 User's Manual. .
The electrical schematic diagram of the system composed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram.
So far the system''s hardware electrical circuit has been determined. Input points: 16 points.
Voltage: DC12/24V.
Current: 4/10mA.
Response time: 10ms.
32 points / a common end.
Negative utility.
20 point terminal station.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation AJ71QC24 User's Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the coomponent image register are changed with the change of the execution of the program AJ71QC24 Manual .
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to thhe adoption of centralized sampling AJ71QC24 Manual .
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
Related products
MITSUBISHI
Coaxial cable module
AJ71LR21
MITSUBISHI Coaxial cable module AJ71LR21
3C-2V/5C-2V coaxial cale. Doule loop.
MITSUBISHI
Network module
AJ71E71N-B5
MITSUBISHI Network module AJ71E71N-B5
10BASE5. When communicating in the PLC n
MITSUBISHI
Upper controller connection module
AJ71C22S1
MITSUBISHI Upper controller connection module AJ71C22S1
RS-422 1 channel. Transfer speed: 38.4k
MITSUBISHI
Ethernet module
AJ71QE71-B5
MITSUBISHI Ethernet module AJ71QE71-B5
Ethernet network module 10BASE5 Control