The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function OMRON E5CN-HTQ2H03D-FLK MANUAL
E5CN-HTQ2H03D-FLK
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type OMRON E5CN-HTQ2H03D-FLK MANUAL.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: - OMRON E5CN-HTQ2H03D-FLK MANUAL.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm). The flange plate of the 4CH channel is used to save the space of the vacuum groove.
A one-time installation of optical fiber, a substantial reduction in thee number of hours (4CH channel flange) E5CN-HTQ2H03D-FLK USER'S MANUAL.
The two ends of the air side of the fiber can be freely cut, can easily draw back.
The two ends of the side of the optical fiber can be freely cut, can easily draw back.
First sscrew fastening type 1CH single channel flange E5CN-HTQ2H03D-FLK USER'S MANUAL.
When used in high temperature environment, high temperature resistant vacuum optical fiber can be used.